Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Year range
1.
Radiol. bras ; 53(2): 122-128, Mar.-Apr. 2020. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1098564

ABSTRACT

Abstract The aim of this report was to present a selection of focal hyperechoic liver lesions of different etiologies, illustrating the wide spectrum of diagnostic possibilities for such lesions in the pediatric population.


Resumo Apresentamos uma seleção de lesões focais hiperecogênicas hepáticas de diversas etiologias, que ilustram o grande espectro de diferentes possibilidades diagnósticas dessas lesões na faixa pediátrica, muito além dos hemangiomas.

4.
Radiol. bras ; 42(1): 7-13, jan.-fev. 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-511794

ABSTRACT

OBJETIVO: Determinar o tamanho do fígado de crianças normais, entre 0 e 7 anos de idade, por ultrassonografia, correlacionando os valores obtidos com: idade, sexo, estatura, peso corporal e índice de massa corpórea. MATERIAIS E MÉTODOS: Foram examinadas 584 crianças saudáveis, subdivididas em 11 grupos etários, sendo medidos o diâmetro crânio-caudal do lobo esquerdo, na linha médio-esternal, e o diâmetro crânio-caudal da superfície posterior do lobo direito, na linha hemiclavicular. Na análise estatística foram aplicados: a) coeficiente de correlação de Pearson (estudo de correlação); b) teste t de Student não-pareado (comparação das medidas entre os sexos); c) modelos de regressão não linear (nomogramas). RESULTADOS: O tamanho hepático apresentou aumento progressivo, do nascimento aos 7 anos de idade, proporcionalmente menor que o crescimento corporal, correlacionado com idade, estatura e peso corporal (r > 0,70), não havendo correlação com índice de massa corpórea (r < 0,11). Não se observou diferença consistente das medidas hepáticas em relação ao sexo. CONCLUSÃO: Valores do tamanho do fígado de crianças normais (entre 0 e 7 anos) foram determinados mediante aplicação de técnica padronizada, verificando-se forte correlação com a idade e indicadores antropométricos. Nomogramas demonstram as variações normais do tamanho hepático na população estudada, com crescimento diferenciado para cada lobo.


OBJECTIVE: The present study was aimed at sonographically determining the liver size in healthy newborns, infants and children under 7 years of age, correlating results with age, sex, height, body weight and body mass index. MATERIALS AND METHODS: A total of 584 healthy children subdivided into 11 age groups were evaluated with measurements of the left lobe craniocaudal diameter at the midsternal line, and the craniocaudal diameter of the right lobe posterior surface at the midclavicular line. The following tests were utilized for statistical analysis: a) Pearson's correlation coefficient (correlation study); b) non-paired Student's t-test (comparison of measures between sexes); c) nonlinear regression models (nomograms). RESULTS: The liver size presented a progressive growth from the birth up to the age of 7, proportionally lower than the body growth, in correlation with age, height and body weight (r > 0.70). Correlation with the body mass index was not observed (r < 0.11). There was no significant difference in liver size between male and female individuals. CONCLUSION: Liver size was sonographically determined in healthy children under the age of 7 by means of a standardized method, demonstrating a strong correlation with age and anthropometric indicators. Nomograms demonstrate the typical variations of the liver size in the population evaluated with a different growth pattern for each hepatic lobe.

5.
São Paulo; s.n; 2008. [129] p. graf, tab, ilus.
Thesis in Portuguese | LILACS | ID: lil-540843

ABSTRACT

INTRODUÇÃO: A biometria hepática por ultra-som é freqüentemente solicitada na investigação diagnóstica de crianças, no entanto, há múltiplos métodos descritos, nenhum com aceitação consensual e carência de valores normais de referência. OBJETIVOS: Determinar o tamanho do fígado de crianças normais, entre 0 e 7 anos de idade, por ultra-sonografia e correlacionar os valores obtidos com as variáveis: idade, sexo, estatura, peso corporal e índice de massa corpórea (IMC). MÉTODOS: Entre 2003 e 2005 foram examinadas 584 crianças saudáveis, com idades entre 0 e 7 anos, aplicando-se método ultra-sonográfico padronizado. A hepatometria foi efetuada em planos de corte longitudinais, estabelecidos por linhas de orientação externas, associadas a reparos anatômicos extra e intra-hepáticos. Foram medidos: a) o diâmetro crânio-caudal do lobo hepático esquerdo, na linha médio-esternal (CCLME) e b) o diâmetro crânio-caudal da superfície posterior do lobo hepático direito, na linha hemiclavicular (CCPLHC). As crianças foram subdivididas em 11 grupos por faixa etária. Para o estudo de correlação foi utilizado o coeficiente de correlação de Pearson. O teste t de Student não-pareado foi aplicado na comparação das medidas entre os sexos e o teste de Bonferroni, para análise de variância das médias por faixa etária. Nomogramas em função da idade foram elaborados mediante modelos de regressão não-linear. RESULTADOS: As medidas hepáticas apresentaram correlação positiva e significante com a idade (r=0,75 para CCLME e 0,80 para CCPLHC), a estatura (r=0,80 para CCLME e 0,85 para CCPLHC) e o peso (r=0,74 para CCLME e 0,82 para CCPLHC), não havendo correlação com o IMC (r<0,11). Observou-se diferença significativa entre os sexos em 3 grupos etários, com valores maiores nos meninos. Observou-se aumento progressivo do tamanho do fígado na faixa etária estudada, proporcionalmente menor que o crescimento corporal e com padrão de crescimento diferenciado para cada um dos lobos...


INTRODUCTION: Several methods to determine sonographic liver size have been reported, none of them consensually accepted; moreover, there is a lack of normal reference values. OBJECTIVES:The proposal of this research is to determine sonographic liver size in normal newbors, infants, and children under 7 year of age and correlate obtained values to age, sex, body height, body weight and body mass index (BMI). METHODS: Between 2003 and 2005, 584 healthy children were examined with sonography. Liver measurements were performed on two standardized longitdinal seccional planes, defined by orientation external lines, related to, both, extra and intra-hepatic anatomic references. Two diameters were measured: a) left lobe cranio-caudal diameter, on mid-sternal line (CCMSL) and b) right lobe posterior surface cranio-caudal diameter, on midclavicular line (PCCMCL). Children were classified acconding to age and sorted in 11 groups. Statistical analysis: Pearsons correlation coefficient was used for correlation study. Unpaired Stutent t-test was applied for comparison of measures acconding to sex. Bonferroni test was used for variance analysis between the means at the different age groups. Nomograms of the liver size related to age were established by non-linear regression models. RESULTS: It was observed positive and significant correlation between liver measurements and age (r=0,75 for CCMSL and 0,80 for PCCMCL), body height (r=0,80 for CCMSL and 0,85 for PCCMCL), and body weight (r=0,74 for CCMSL and 0,82 for PCCMCL). No relevant correlation with BMI (r<0,11) was found. Significant difference between sexes were found in 3 age groups, with higher values in males. Liver size measurements showed progressive increase, proportionally lesser than body height and with a different growth pattern for each lobe: the left lobe presented major growth in the first 3 years of age, while the right lobe presented gradual and progressive growth from birth to 7 years of age...


Subject(s)
Humans , Male , Female , Infant, Newborn , Child , Biometry , Child , Liver , Organ Size , Ultrasonography
6.
Radiol. bras ; 36(2): 63-70, mar.-abr. 2003. ilus, tab
Article in Portuguese | LILACS | ID: lil-337814

ABSTRACT

OBJETIVO: Padronizar método ultra-sonográfico de biometria hepática em crianças, visando estabelecer maior precisão nos planos de corte e minimizar o fator operador-dependência; testar a reprodutibilidade intra-observador. CASUíSTICA E MÉTODO: A hepatometria ultra-sonográfica foi realizada em 32 crianças, entre 0 e 6 anos de idade, sem doença hepática ou das vias biliares. Todas as crianças foram examinadas por um mesmo observador, em duas ocasiões diferentes (exames 1 e 2). Os planos seccionais foram estabelecidos inter-relacionando linhas de orientação externas a reparos anatômicos intra-abdominais, extra e intra-hepáticos. Para análise comparativa das medidas dos exames 1 e 2 foi utilizado o teste t pareado. O coeficiente de Pearson foi empregado para análise de correlação: a) dos parâmetros entre si; b) entre a idade das crianças e a diferença das medidas dos exames 1 e 2. RESULTADOS: A análise estatística não houve: a) diferença significante no estudo da variabilidade intra-observador; b) correlação significante entre a diferença das medidas e as idades dos pacientes. Verificamos que os parâmetros estão, no geral, direta e altamente correlacionados entre si (r > 0,60). CONCLUSÃO: O método é reprodutível por um mesmo observador. As medidas dos diâmetros crânio-caudal na linha médio-esternal e crânio-caudal posterior na linha hemiclavicular, usando referenciais anatômicos intra-hepáticos, mostraram-se precisas e mais práticas que as demais


OBJECTIVE: The objectives of this study are: (1) to standardize the sonographic biometry method to determine the size of the liver in children in order to obtain a greater precision of the section planes and to minimize operator-dependant error; (2) to test intra-observer reproducibility. CASUISTIC AND METHOD: Sonographic measurements of the liver were performed by a single examiner in 32 children (aged 0 to 6 years) with no liver or biliary system disease. The measurements were done in two different occasions (exams 1 and 2) to determine reproducibility. The section planes were based on external orientation lines related to intra-abdominal anatomic references, both extra and intra-hepatic. The values obtained in exams 1 and 2 were compared using a Student's paired t-test. The Pearson's coefficient was employed to determine the correlation among parameters as well as the correlation between the children's age and the difference in the values of exams 1 and 2. RESULTS: The statistical analysis revealed no significant intra-observer variability and no significant correlation between measurements' difference and children's age. In general, parameters were directly and highly correlated (r > 0.60). CONCLUSION: We concluded that the method is reproducible when performed by a same examiner. The measurements of the cranio-caudal diameter at the midsternal line and the posterior cranio-caudal diameter at the midclavicular line, based on intra-hepatic anatomic references, were precise and easier to perform than other routine measurements.


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Liver/anatomy & histology , Liver , Hepatomegaly , Body Weights and Measures/methods , Biometry/methods , Reproducibility of Results
7.
Radiol. bras ; 35(5): 307-309, set.-out. 2002. ilus
Article in Portuguese | LILACS | ID: lil-335134

ABSTRACT

Os autores descrevem dois casos em que se utilizou a ultra-sonografia intra-operatória como método auxiliar à ressecção cirúrgica de insulinomas pancreáticos. Ressaltamos a importância desta técnica, principalmente nos casos em que estes tumores não foram localizados adequadamente por outros métodos no estudo pré-operatório, evitando-se ressecções amplas desnecessárias e reduzindo as complicações pós-operatórias.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Insulinoma , Pancreatic Neoplasms , Insulinoma , Intraoperative Period , Outcome and Process Assessment, Health Care
SELECTION OF CITATIONS
SEARCH DETAIL